| Technical Specifications |
Performance/
Scalability/Flexibility |
- 1 or 2 PA-8900 processors–800 MHz with 1.5 MB L1 cache/64 MB L2 cache (rp3410-2); 2 or 4 PA-8900 processors–800 MHz and 1.0 GHz with 1.5 MB L1 cache/64 MB L2 cache (rp3440-4)
- 6 GB memory capacity (rp3410-2); 32 GB memory capacity (rp3440-4)
- 2 PCI-X I/O card slots (rp3410-2); 4 PCI-X I/O card slots (rp3440-4)
- 1.5 GB/s aggregate I/O slot bandwidth (rp3410-2); 2.5 GB/s aggregate I/O slot bandwidth (rp3440-4)
- Rack and standalone server solutions
- 3 internal hot-plug disk bays and 1 internal removable media bay (DVD or DAT)
- Hot-swap, redundant power supplies
- Redundant (N+1) input power
- Hot-swap, redundant cooling fans
|
| Operating system |
HP-UX 11i v1 and HP-UX 11i v2 |
| Availability |
- Dynamic CPU and memory allocation/de-allocation
- Memory chip-sparing technology
- Error checking and correction (ECC) on all CPU, cache, memory, and I/O paths
- Online addition and replacement of PCI I/O cards
- Redundant power inputs for dual grid connections
- N+1 hot-swappable fans and power supplies
|
| Connectivity |
- Core I/O: 10/100/1000Base-T LAN, Ultra160 SCSI, management LAN, 3 serial ports
- Add-in cards: See Options & Accessories
|
| Manageability |
Central point of management–HP Systems Insight Manager provides a single point of administration and integrates the following tools for configuration, fault and workload management:
- Configuration management
– HP Ignite-UX for installation and deployment of the operating system
– HP Software Distributor-UX for software and patch management
– HP System Administration Manager for HP-UX system administration
– WBEM for consistent management
- Fault management
– HP Event Monitoring Service for fault management
– Management Processor for comprehensive remote server management of HP-UX
- Workload management
– HP-UX Kernel Configuration for easy, dynamic kernel parameter changes
– HP Process Resource Manager for HP-UX resource management (optional)
– HP-UX Workload Manager for workload management based upon prioritized service-level objectives (optional)
|
| Investment protection and flexibility |
- Chassis designed for future generations of PA-RISC
- In-box upgradeability to Intel Itanium processors
|
| Rack-optimized design |
- Rackmount solution offering allows server to fit into 2U (8.6 cm height) space in all HP racks (Rack System/E and 10000 series rack)
- AB241A: HP rack kit for HP 9000 rp3400 Series Servers
- AB242A: HP pedestal kit for HP 9000 rp3400 Series Servers
|
| Physical and Environmental Specifications |
| Physical dimensions |
Height
Width
Depth |
3.4 in. (86 mm); 2U EIA
19 in. (482 mm)
26.8 in. (680 mm)
|
Physical dimensions
(standalone) |
Height
Width
Depth |
19.5 in. (495 mm)
11.7 in. (297 mm)
26.5 in. (672 mm)
|
| Net weight |
Maximum configuration |
56 lb. (25 kg) |
| Temperature |
Operating
Non-operating
Maximum rate of temperature change |
+41° to +95° F (+5° to +35° C)
–40° to +158° F (–40° to +70° C)
18° F (10° C) per hr with tape media, 36° F (20° C) per hr without tape media
|
| Humidity |
Operating |
15% to 80% relative |
| Altitude |
Maximum operating
Maximum non-operating |
10,000 ft. (3000 m)
15,000 ft. (4500 m)
|
| Power requirements |
Input current
Line frequency
Maximum power input |
100–127 V ~8.0
50–60 Hz
714 W
|
| Power supply |
Maximum output |
650 W |
| |
 |
 |