| Technical Specifications |
Performance/
Scalability/Flexibility |
- 2 to 16 processors
- PA-8900 (1.0 GHz or 1.1 GHz with 1.5 MB L1 cache/64 MB combined L2 cache)
- PA-8800 (900 MHz or 1.0 GHz with 1.5 MB L1 cache/32 MB combined L2 cache)
- 1 to 2 cell boards (each cell: 2–8 processors and 2 to 64 GB memory)
- 2 to 128 GB memory capacity
- 15 PCI-X internal hot-plug I/O card slots
- 4 internal disk bays and 1 internal removable media bay (DVD + RW or DAT)
- Up to 2 hardware partitions (nPars)
- Support for up to 16 virtual partitions (vPars)
- 16 GB/s aggregate I/O slot bandwidth
- Rack and standalone server solutions
- Hot-swap, redundant power supplies
- Redundant (2N+1) input power
- Hot-swap, redundant cooling fans
|
| Operating system |
HP-UX 11i v1 and HP-UX 11i v2 (choice of Foundation, Enterprise, Mission-Critical, and Technical Computing operating environments) |
| Availability |
- Dynamic CPU and memory allocation/de-allocation
- Memory chip-sparing technology
- Hot-plug cell boards
- Hot-plug fans
- Error checking and correction (ECC) on all CPU, cache, memory, and I/O paths
- Online addition and replacement of PCI-X I/O cards
- Redundant power inputs for dual grid connections
- N+1 hot-swappable fans and power supplies
- Hot-spare Instant Capacity-delete on demand - CPU functionality
- Hardware partitions (nPars)
|
| Connectivity |
- Core I/O: 10/100/1000Base-T LAN, Ultra3 SCSI, management LAN, 3 serial ports
- Add-in cards: ATM, Token Ring, FDDI, 1000Base-SX, 1000Base-T, 10/100Base-T, Ultra2, Ultra3, Fibre Channel, terminal MUX, Hyperfabric,combo cards
|
| Manageability |
Deploy:
- HP Partition Manager
- HP Ignite-UX for installation and deployment of the operating system
- HP Software Distributor-UX for software and patch management
Monitor:
- Built-in management processor for comprehensive remote server management
- HP Servicecontrol Manager for centralized HP-UX server management
Optimize:
- HP-UX 11i Virtual Server Environment (VSE) including HP-UX 11i Virtual Partitions and hard partitions
- HP Process Resource Manager (PRM) for HP-UX resource management
- HP-UX Workload Manager (WLM) for HP-UX workload management based upon service-level objectives
- HP OpenView Glanceplus Pak
Enterprise:
- HP OpenView suite for infrastructure, service, and business process management
- HP Systems Insight Manager to manage faults, assets, security, and configurations across HP-supported environments
|
| Rack-optimized design |
- Rackmount solution offering allows server to fit into 10U (44.45 cm height) space in all HP racks (Rack System/E and 10000 series rack)
- J1530B: HP field rack kit
- J1530BZ: HP factory rack kit
|
| Physical and Environmental Specifications |
| Physical dimensions |
Height
Width
Depth |
Racked chassis: 17.5 in. (445 mm); 10U EIA
Standalone chassis: 20.75 in. (527 mm)
19 in. (483 mm)
30 in. (762 mm)
|
| Net weight |
Maximum configuration |
220 lb. (99.8 kg) |
| Temperature |
Operating
Non-operating
Maximum rate of temperature change |
+41° to +95° F (+5° to +35° C); 86° F (30° C) @ 10,000 ft. (3000 m)
For altitudes > 5,000 ft., derate max. temp. by 1.8 F° (1° C) per 1000 ft. (300 m)
–40° to +158° F (–40° to +70° C)
36° F (20° C) per hr
|
| Humidity |
Operating |
15% to 80% RH non-condensing: max. wet bulb = 78° F (26°C) |
| Altitude |
Maximum operating
Maximum non-operating |
10,000 ft. (3000 m)
15,000 ft. (4500 m) |
| Power requirements |
Input current
Line frequency
Typical power dissipation |
200–240 V
50–60 Hz
2015 VA (max. configuration)
10.1 A @ 200 Vac
|
| Regulatory |
Safety
Electromagnetic interference
Power line LF emissions |
UL listed, CUL certified, TÜV GS Mark, compliant with EN 60950
Complies with FCC rules and regulations, Part 15 as a Class A Digital Device;
Manufacturer's Declaration to EN55022 Level A, VCCI
Registered, Class I, Korea RLL
Europe: EN 61000-3-2; Europe: EN 61000-3-3
|
| |
 |
 |