| Technical Specifications |
Performance/
Scalability/Flexibility |
- Up to 8 dual-core HP PA-RISC PA-8900 processors
- PA-8900 (1.068 GHz with 3 MB L1 cache/64 MB combined L2 cache)
- 1 to 2 cell boards (each cell can accommodate up to 4P/8C and up to 64 GB of memory)
- 2 to 128 GB memory capacity per system
- 15 PCI-X hot-plug I/O card slots
- 4 internal disk bays and 1 internal removable media bay (DVD + RW or DAT)
- Up to 2 hardware partitions (nPars)
- Support for up to 16 virtual partitions (vPars)
- 23 GB/s aggregate I/O slot bandwidth
- Hot-swap, redundant power supplies
- Redundant (2N+1) input power
- Hot-swap, redundant cooling fans
- Rack solutions
|
| Operating system |
HP-UX 11i v1 (choice of Foundation,Enterprise, Mission-Critical, and Technical Computing operating environments). |
| Availability |
- Dynamic CPU and memory allocation/de-allocation
- Hot-plug cell boards
- Hot-plug fans
- Error checking and correcting (ECC) on all CPU, cache, memory, and I/O paths
- Online addition and replacement of PCI I/O cards
- Redundant power inputs for dual-grid connections
- Redundant clock sources
- Management processor failover (core I/O)
- N+1 hot-swappable fans and power supplies
- Hot-spare Instant Capacity CPU functionality (requires Instant Capacity CPUs)
- Hardware partitions (nPars)
|
| Connectivity |
- Core I/O
- 10/100/1000Base-T Ethernet
- Ultra320 SCSI
- 10/100Base-T management LAN
- 1 RS-232 serial port for local console
- Add-in cards: Various Networking (Ethernet), storage (Fibre Channel, SCSI), network/storage combo and specialized IO cards
|
| Rack-optimized design |
- Rackmount solution offering allows server to fit into 10U (44.45 cm
height) space in all HP racks (Rack System/E and 10000 series rack)
- J1530B: HP field rack kit
- J1530BZ: HP factory rack kit
|
| Physical and Environmental Specifications |
| Physical dimensions |
Height
Width
Depth |
Racked chassis: 17.5 in. (445 mm); 10U EIA
Standalone chassis: 20.75 in. (527 mm)
19 in. (483 mm)
30 in. (762 mm)
|
| Net weight |
Maximum configuration |
220 lb. (99.8 kg) |
| Temperature |
Operating
Non-operating
Maximum rate of temperature change |
+41° to +95° F (+5° to +35° C); 86° F (30° C) @ 10,000 ft. (3000 m)
For altitudes > 5,000 ft., derate max. temp. by 1.8 F° (1° C) per 1000 ft. (300 m)
–40° to +158° F (–40° to +70° C)
36° F (20° C) per hr
|
| Humidity |
Operating |
15% to 80% RH non-condensing: max. wet bulb = 78° F (26°C) |
| Altitude |
Maximum operating
Maximum non-operating |
10,000 ft. (3000 m)
15,000 ft. (4500 m) |
| Power requirements |
Input current
Line frequency
Typical power dissipation |
200–240 V
50–60 Hz
2078 VA (max. configuration)
10.39 A @ 200 V AC
|
| Regulatory |
Safety
Electromagnetic interference
Power line LF emissions |
UL listed, CUL certified, TÜV GS Mark, compliant with EN 60950
Complies with FCC rules and regulations, Part 15 as a Class A Digital Device;
Manufacturer's Declaration to EN55022 Level A, VCCI
Registered, Class I, Korea RLL
Europe: EN 61000-3-2; Europe: EN 61000-3-3
|
| |
 |
 |