| Configuration Options |
Superdome with new sx2000 chipset (16 processors) |
Superdome with new sx2000 chipset (32 processors) |
Superdome with new sx2000 chipset (64 processors) |
| Processors |
2 - 16 |
2 - 32 |
6 - 64 |
| Cores |
4 - 32 |
4 - 64 |
12 - 128 |
| 4-CPU Cell Boards |
1 - 4 |
1 - 8 |
3 - 16 |
| Maximum memory per partition |
512 GB |
1 T B |
2 TB |
| Max. processors per partition |
32 |
64 |
128 |
Total hot-swap
PCI-X I/O slots |
48 slots
(8 slots @ 2,133MB/s;
16 slots @ 533MB/s;
24 slots @ 1,066MB/s) |
48/96 slots *
(16 slots @ 2,133MB/s;
32 slots @ 533MB/s;
48 slots @ 1,066MB/s) |
96/192 slots *
(32 slots @ 2,133MB/s;
96 slots @ 1,066MB/s;
64 slots @ 533MB/s) |
| Hot-swap, redundant power supplies (N+1 included) |
4 |
6 |
12 |
| I/O Fans |
5 |
5 |
10 |
| Hot-swap, redundant blowers or fans (N+1 included) |
4 |
4 |
8 |
| Virtual partitions |
32 |
64 |
128 |
| Physical (hard) partitions |
4 |
8 |
16 |
| Crossbar bandwidth (Peak) |
27.3 GB/s |
27.3 GB/s |
27.3 GB/s |
| Cell controller to I/O subsystem bandwidth (Peak) |
7.7 GB/s |
7.7 GB/s |
7.7 GB/s |
| I/O bandwidth (Peak) |
8GB/s |
16GB/s |
32GB/s |
| Memory bandwidth (Peak) |
68.3 GB/s |
136.5 GB/s |
273.1 GB/s |
| Operating system |
HP-UX 11i v1, v2, v3 with HP Virtual Server Environment (choice of Enterprise, Mission-Critical, Enterprise, or Foundation Operating Environment) |
HP-UX 11i v1, v2, v3 with HP Virtual Server Environment (choice of Enterprise, Mission-Critical, Enterprise, or Foundation Operating Environment) |
HP-UX 11i v1, v2, v3 with HP Virtual Server Environment (choice of Enterprise, Mission-Critical, Enterprise, or Foundation Operating Environment) |
| Configuration Options |
Superdome with sx1000 chipset (16 processors) |
Superdome with sx1000 chipset (32 processors) |
Superdome with sx1000 chipset (64 processors) |
| Processors |
2 - 16 |
2 - 32 |
6 - 64 |
| Cores |
4 - 32 |
4 - 64 |
12 - 128 |
| 4-CPU Cell Boards |
1 - 4 |
1 - 8 |
3 - 16 |
| Maximum memory per partition |
512 GB |
1 T B |
2 TB |
| Max. processors per partition |
32 |
64 |
128 |
Total hot-swap
PCI-X I/O slots |
48 slots
(8 slots @ 2,133MB/s;
16 slots @ 533MB/s;
24 slots @ 1,066MB/s) |
48/96 slots *
(16 slots @ 2,133MB/s;
32 slots @ 533MB/s;
48 slots @ 1,066MB/s) |
96/192 slots *
(32 slots @ 2,133MB/s;
96 slots @ 1,066MB/s;
64 slots @ 533MB/s) |
| Hot-swap, redundant power supplies (N+1 included) |
4 |
6 |
12 |
| I/O Fans |
5 |
5 |
10 |
| Hot-swap, redundant blowers or fans (N+1 included) |
4 |
4 |
8 |
| Virtual partitions |
32 |
64 |
128 |
| Physical (hard) partitions |
4 |
8 |
16 |
| Crossbar bandwidth (Peak) |
27.3 GB/s |
27.3 GB/s |
27.3 GB/s |
| Cell controller to I/O subsystem bandwidth (Peak) |
7.7 GB/s |
7.7 GB/s |
7.7 GB/s |
| I/O bandwidth (Peak) |
8GB/s |
16GB/s |
32GB/s |
| Memory bandwidth (Peak) |
68.3 GB/s |
136.5 GB/s |
273.1 GB/s |
| Operating system |
HP-UX 11i v1, v2, v3 with HP Virtual Server Environment (choice of Enterprise, Mission-Critical, Enterprise, or Foundation Operating Environment) |
HP-UX 11i v1, v2, v3 with HP Virtual Server Environment (choice of Enterprise, Mission-Critical, Enterprise, or Foundation Operating Environment) |
HP-UX 11i v1, v2, v3 with HP Virtual Server Environment (choice of Enterprise, Mission-Critical, Enterprise, or Foundation Operating Environment) |
| Physical Dimensions |
| Height |
1.96m (77.2 in) |
1.96m (77.2 in) |
1.96m (77.2 in) |
| Width |
762mm (30 in) |
762mm (30 in) |
1,524mm (60 in) |
| Depth |
1,220mm (48 in) |
1,220mm (48 in) |
1,220mm (48 in) |
| Weight |
500kg (1,102 lb) |
598kg (1,318 lb) |
1,196kg (2,636 lb) |
| Environmental Specifications |
| Operating temperature |
20°C to 30°C
(68°F to 86°F) |
20°C to 30°C
(68°F to 86°F) |
20°C to 30°C
(68°F to 86°F) |
| Non-operating temperature |
–40°C to 70°C
(–40°F to 158°F) |
–40°C to 70°C
(–40°F to 158°F) |
–40°C to 70°C
(–40°F to 158°F) |
| Maximum rate of temperature change |
20°C/hr (36°F/hr) |
20°C/hr (36°F/hr) |
20°C/hr (36°F/hr) |
| Operating relative humidity |
15% to 80%
@ 30°C (86°F) |
15% to 80%
@ 30°C (86°F) |
15% to 80%
@ 30°C (86°F) |
| Non-operating relative humidity |
90% @ 65°C (149°F) |
90% @ 65°C (149°F) |
90% @ 65°C (149°F) |
| Operating altitude |
3000m
(10,000 ft.) max |
3000m
(10,000 ft.) max |
3000m
(10,000 ft.) max |
| Non-operating altitude |
4500m
(15,000 ft.) max |
4500m
(15,000 ft.) max |
4500m
(15,000 ft.) max |
 |
 |
 |
 |