HP Integrity Non Stop Servers

Overview

When service levels are paramount, customers can trust HP Integrity NonStop servers for their most critical business applications.

HP introduces the Integrity NonStop server, designed to deliver the industry’s highest application service levels at the best ROI and TCO in its class—based on standards such as the Intel® Itanium® 2 processor, SQL, Web services, J2EE software architecture, and more.

With today’s sophisticated architectures, decision makers often compromise between availability and scalability and are still left with complex, expensive-to-manage infrastructures. HP Integrity NonStop servers deliver these capabilities out of the box significantly simplifying the infrastructure and reducing costs.

HP Integrity NonStop servers offer enterprise customers superior choice providing:

  • Highest level of application availability with fail-safe data integrity
  • Ultimate scalability with uncompromised availability
  • Flexible platform for heterogeneous environments
  • Standards-based architecture powered by the Intel® Itanium® 2 processor
  • Built to last—an average system runs 20 years without scheduled downtime
HP
HP Integrity Non Stop

Specification

  HP Integrity NonStop NS16000 Server - Intel® Itanium® 2 processors HP Integrity NonStop NS14000 Server - Intel® Itanium® 2 processors HP Integrity NonStop NS1000 Server - Intel® Itanium® 2 processors
Processors Linear scalability from 2 to 4,080 processors Linear scalability from 2 to 2,040 processors Linear scalability from 2 to 8 processors per system
Processor type Itanium 2 (1.6-GHz) Itanium 2 (1.5-GHz) Itanium 2 (1.3 GHz) processors
Memory 4 to 16 GB 4 to 8 GB 4 to 8 GB
Disk Drives 73 GB, 146 GB, and HP StorageWorks XP12000 Disk Array 73 GB, 146 GB, and HP StorageWorks XP12000 Disk Array 73 GB, 146 GB, and HP StorageWorks XP12000/XP10000
Disk Array
Architecture HP NonStop Advanced Architecture with Triple Modular Redundancy (TMR) or Dual Modular Redundancy (DMR) technology HP NonStop Advanced Architecture with Triple Modular Redundancy (TMR) or Dual Modular Redundancy (DMR) technology HP NonStop Value Architecture with software fault tolerance and commercial hardware data integrity
Altitude Operating: 10,000 ft (3,000 m) maximum Nonoperating: 15,000 ft (4,500 m) maximum Operating: 10,000 ft (3,000 m) maximum
Nonoperating: 40,000 ft (12,000 m) maximum
Operating: 10,000 ft (3,000 m) maximum
Nonoperating: 40,000 ft (12,000 m) maximum
Temperature Operating: 68° to 86°F (20° to 30°C) Nonoperating: –40° to +158°F (–40° to +70°C) Maximum rate of temperature change:
36°F (20°C) per hour
Operating: 40° to 100°F (5° to 35°C)
Nonoperating: –40° to 150°F (–40° to 66°C)
Maximum rate of temperature change: 36°F (20°C) per hour
Operating: 40° to 100°F (5° to 35° C)
Nonoperating: –40° to +150°F (–40° to +66° C)
Maximum rate of temperature change: 36°F
(20° C) per hour
Humidity Operating: 15% to 80% relative noncondensing maximum
Nonoperating: 90% maximum at 149°F (65°C)
Operating: 10% to 85% relative noncondensing maximum
Nonoperating: 95% maximum at 150°F (66°C)
Operating: 10% to 85% relative noncondensing maximum
Nonoperating: 95% maximum at 150°F (66°C)
Dimensions Height: 77.2 in (1,960 mm)
Width: 30 in (762 mm)
Depth: 48 in (1,220 mm)
Height: 79.0 in (2,007 mm)
Width: 24 in (610 mm)
Depth: 45 in (1,143 mm)
Height: 78.7 in (199.9 cm)
Width: 24 in (60.96 cm)
Depth: 36.69 in (100.8 cm)
Weight 1,102 lb (500 kg) 1,060 lb (481 kg) 1,060 lb (481 kg)
Power supply Typical power dissipation: 3800 VA (maximum configuration)
Input current: 10.2 A @ 200 VAC
AC input power: 200–240 V, 50–60 Hz
Typical power dissipation: 2,200 VA (maximum configuration)
Input current: 14 A @ 200 VAC
AC input power: 200–240 V, 50–60 Hz
Typical power dissipation: 2,200 VA (maximum configuration)
Input current: 14 A @ 200 VAC
AC input power: 200–240 V, 50–60 Hz
Safety UL listed, CUL certified, TÜV GS Mark, compliant with EN 60950 CUL certified, compliant with EN 60950 CUL certified, compliant with EN 60950
Electromagnetic interference Complies with FCC rules and regulations, Part 15, as a Class A Digital Device; manufacturer’s declaration to EN 55022 Level A, VCCI registered, Class I, Korea RLL Complies with FCC rules and regulations, Part 15, as a Class A Digital Device; manufacturer’s declaration to EN 55022 Level A Complies with FCC rules and regulations, Part 15, as a Class A Digital Device; manufacturer’s declaration to EN 55022 Level A
Power line LF emissions EN 61000-3-2 (Europe); EN 61000-3-3 (Europe) EN 61000-3-2 (Europe); EN 61000-3-3 (Europe) EN 61000-3-2 (Europe); EN 61000-3-3 (Europe)

 

 

 

To enquire about this product
(including spares, parts, maintenance, service & support contracts)
call us on +44 (0)1937 840420 or email us