HP Integrity NonStop NS16000 Server - Intel® Itanium® 2 processors |
HP Integrity NonStop NS14000 Server - Intel® Itanium® 2 processors |
HP Integrity NonStop NS1000 Server - Intel® Itanium® 2 processors |
| Processors |
Linear scalability from 2 to 4,080 processors |
Linear scalability from 2 to 2,040 processors |
Linear scalability from 2 to 8 processors per system |
| Processor type |
Itanium 2 (1.6-GHz) |
Itanium 2 (1.5-GHz) |
Itanium 2 (1.3 GHz) processors |
| Memory |
4 to 16 GB |
4 to 8 GB |
4 to 8 GB |
| Disk Drives |
73 GB, 146 GB, and HP StorageWorks XP12000 Disk Array |
73 GB, 146 GB, and HP StorageWorks XP12000 Disk Array |
73 GB, 146 GB, and HP StorageWorks XP12000/XP10000
Disk Array |
| Architecture |
HP NonStop Advanced Architecture with Triple Modular Redundancy (TMR) or Dual Modular Redundancy (DMR) technology |
HP NonStop Advanced Architecture with Triple Modular Redundancy (TMR) or Dual Modular Redundancy (DMR) technology |
HP NonStop Value Architecture with software fault tolerance and commercial hardware data integrity |
| Altitude |
Operating: 10,000 ft (3,000 m) maximum Nonoperating: 15,000 ft (4,500 m) maximum |
Operating: 10,000 ft (3,000 m) maximum
Nonoperating: 40,000 ft (12,000 m) maximum |
Operating: 10,000 ft (3,000 m) maximum
Nonoperating: 40,000 ft (12,000 m) maximum |
| Temperature |
Operating: 68° to 86°F (20° to 30°C) Nonoperating:
–40° to +158°F (–40° to +70°C) Maximum rate
of temperature change:
36°F (20°C) per hour |
Operating: 40° to 100°F (5° to 35°C)
Nonoperating: –40° to 150°F (–40° to 66°C)
Maximum rate of temperature change: 36°F (20°C) per hour |
Operating: 40° to 100°F (5° to 35° C)
Nonoperating: –40° to +150°F (–40° to +66° C)
Maximum rate of temperature change: 36°F
(20° C) per hour |
| Humidity |
Operating: 15% to 80% relative noncondensing maximum
Nonoperating: 90% maximum at 149°F (65°C) |
Operating: 10% to 85% relative noncondensing maximum
Nonoperating: 95% maximum at 150°F (66°C) |
Operating: 10% to 85% relative noncondensing maximum
Nonoperating: 95% maximum at 150°F (66°C) |
| Dimensions |
Height: 77.2 in (1,960 mm)
Width: 30 in (762 mm)
Depth: 48 in (1,220 mm) |
Height: 79.0 in (2,007 mm)
Width: 24 in (610 mm)
Depth: 45 in (1,143 mm) |
Height: 78.7 in (199.9 cm)
Width: 24 in (60.96 cm)
Depth: 36.69 in (100.8 cm) |
| Weight |
1,102 lb (500 kg) |
1,060 lb (481 kg) |
1,060 lb (481 kg) |
| Power supply |
Typical power dissipation: 3800 VA (maximum configuration)
Input current: 10.2 A @ 200 VAC
AC input power: 200–240 V, 50–60 Hz |
Typical power dissipation: 2,200 VA (maximum configuration)
Input current: 14 A @ 200 VAC
AC input power: 200–240 V, 50–60 Hz |
Typical power dissipation: 2,200 VA (maximum configuration)
Input current: 14 A @ 200 VAC
AC input power: 200–240 V, 50–60 Hz |
| Safety |
UL listed, CUL certified, TÜV GS Mark, compliant with EN 60950 |
CUL certified, compliant with EN 60950 |
CUL certified, compliant with EN 60950 |
| Electromagnetic interference |
Complies with FCC rules and regulations, Part 15, as a Class A Digital
Device; manufacturer’s declaration to EN 55022 Level A, VCCI
registered, Class I, Korea RLL |
Complies with FCC rules and regulations, Part 15, as a Class A Digital
Device; manufacturer’s declaration to EN 55022 Level A |
Complies with FCC rules and regulations, Part 15, as a Class A Digital
Device; manufacturer’s declaration to EN 55022 Level A |
| Power line LF emissions |
EN 61000-3-2 (Europe); EN 61000-3-3 (Europe) |
EN 61000-3-2 (Europe); EN 61000-3-3 (Europe) |
EN 61000-3-2 (Europe); EN 61000-3-3 (Europe) |